Power Delivery
Type-C Breakout
  User Calibration Kit for PDT

  PD Analyser Adapter for PDT

  Software Downloads

        Buy
 
 
 
 
 
 
 
 

USB Power Delivery Test Equipment

Type-C Cable Breakout Unit

The Type-C Breakout Unit allows investigation of the signals in a Type-C cable connection which can be examined and interrupted. These signals are:

  • CC1
  • CC2
  • SBU1
  • SBU2
  • VBUS

The following signals can be monitored but not interrupted:

  • D+
  • D-

The Type-C Breakout Unit is intended for use by developers of PD and Type-C Functionality devices as it provides the ability to access the appropriate signal in a Type-C cable without affecting the operation..

The VBUS connection is provided with a current measuring loop to allow VBUS current measurements using an appropriate scope.

Technical Details

Table 1 - Connection details
C-Plug

Test Point /
Disconnect Provision

C-Receptacle
Pin No Signal Name Pin No Signal Name

A4, B4, A9, B9

VBUS
Test Point 'VBUS R' Test Point 'VBUS P' A4, B4, A9, B9
VBUS
Bridge VBUS with straight link or current measurement loop
A7
(B7 no connect)
D-
Test Point 'USB Data D-'
plus associated GND test point
A7, B7 D-
A6
(B6 no connect)
D+ Test Point 'USB Data D+' plus associated GND test point A6, B6 D+
A1, B1, A12, B12 GND Test Point 'GND' x 3 A1, B1, A12, B12 GND
A5 CC Test Point 'CC R'
plus associated GND test point
Test Point 'CC P'
plus associated GND test point
A5 CC1
Bridge CC with link header
B5 VCONN Test Point 'VCONN R'
plus associated GND test point
Test Point 'VCONN P'
plus associated GND test point
B5 CC2
Bridge VCONN with link header
A8 SBU1 Test Point 'SBU1 R'
plus associated GND test point
Test Point 'SBU1 P'
plus associated GND test point
SBU1 A8
Bridge SBU1 with link header
B8 SBU2 Test Point 'SBU2 R'
plus associated GND test point
Test Point 'SBU2 P'
plus associated GND test point
SBU2 B8
Bridge SBU2 with link header
A2 TX1+ Direct connection A2 TX1+
A3 TX1- Direct connection A3 TX1-
B11 RX1+ Direct connection B11 RX1+
B10 RX1- Direct connection B10 RX1-
B2 TX2+ Direct connection B2 TX2+
B3 TX2- Direct connection B3 TX2-
A11 RX2+ Direct connection A11 RX2+
A10 RX2- Direct connection A10 RX2-
Shield S Direct connection S Shield

Note 1: For convenience the signal names assume that the connector is the normal way up. If the conector is flipped then CC and VCONN swap places with SBU1 and SBU2 respectively.
Note 2: Bridges should normally be made unless required to be broken for engineering development purposes.

 

The Type-C Breakout Unit is supplied in a protective carrying case which also includes a VBUS current measuring loop, for use with an oscilloscope current probe.